Healthcare · Moraph software

Medical Device Cybersecurity Hub

Know every connected medical device, what it is exposed to, and what is being done about it

At a glance

For
Clinical engineering and healthcare technology management teams
What it does
Inventory → Assess → Remediate → Govern
Type and deployment
Moraph software, running in Moraph Apps. Moraph cloud, With a managed service.
Availability
Generally available. What this means Release notes
Works alongside
Clinical engineering system (CMMS), Network discovery tools, Vulnerability and advisory feeds, IT service management and 3 more

Request a demonstration See the walkthrough

What it does not do

  • The Hub does not scan or probe devices itself. It relies on your clinical engineering records and the network discovery tools you already run, and its inventory is only as complete as those sources.
  • It does not patch devices. Patches and upgrades are applied by your clinical engineering staff or the manufacturer, once the manufacturer has validated them.
  • Vulnerability matching depends on accurate model and software version data and on what manufacturers publish. Matches are confirmed by an analyst before they become findings.

All 8 limitations

Overview

What you are buying

The Medical Device Cybersecurity Hub keeps one inventory of the connected medical devices in your hospitals, built from the exports of your clinical engineering system and network discovery tools. It matches each device to the published vulnerabilities and manufacturer advisories your team records or loads, tracks patch status and compensating controls, and routes remediation and risk-acceptance decisions to the right people. Clinical engineering, security and clinical departments work from the same record, with the evidence kept for auditors and your risk committee.

The problem it solves

Most hospitals track infusion pumps, imaging systems, monitors and lab analyzers in a clinical engineering system that knows the asset tag and maintenance history but not the software version or network exposure, while the security team sees IP addresses with no idea what clinical device sits behind them. Manufacturer advisories arrive by email, patches can only be applied once the manufacturer has validated them, and many devices run operating systems that are no longer supported. When a new vulnerability is published, nobody can say quickly which devices are affected, where they are, or what has been done to protect them.

  • Clinical engineering and security keep separate, incomplete device lists
  • Advisories and vulnerabilities are matched to devices by hand, if at all
  • Patch status, compensating controls and manufacturer approval are tracked in spreadsheets
  • Risk acceptance for devices that cannot be patched is rarely documented or reviewed
Who uses it and related requirements

Who uses it

  • Clinical engineering and healthcare technology management teams
  • Medical device and IoMT security analysts in the information security team
  • CISOs and IT risk leaders who answer for device risk
  • Clinical department and biomedical leaders who own the devices and approve downtime
  • Supply chain and procurement teams who review device security before purchase

Related requirements

Listing a requirement here is not a statement that the product meets it; meeting it remains your organization's responsibility.

See how it works

A short walkthrough

Illustrative screens with fictional sample data. They show the workflow, not any client’s data or configuration, and the layout of the product itself differs. A live demonstration uses the product with sample data.

  1. Step 1

    The device inventory

    One list of connected medical devices, combining clinical engineering records with what the network shows.

    Asset tagDevice typeLocationSoftwareOpen findingsSupport
    BX-10482Infusion pumpExample General, 4 Westv2.32 highSupported
    BX-20917Patient monitorExample General, ICUv5.11 mediumSupported
    BX-31554CT workstationExample General, ImagingLegacy OS3 highEnd of support
    BX-40126Lab analyzerExample Clinic, Labv8.0NoneSupported
    UnmatchedUnknownExample General, 2 EastNot observedNot assessedNeeds review
    One list of connected medical devices, combining clinical engineering records with what the network shows.
  2. Step 2

    A matched vulnerability

    Each advisory match shows the affected devices and the factors behind the score, for an analyst to confirm.

    Example infusion pump model · Manufacturer advisory (fictional)

    Affected versions
    v2.0 to v2.3
    Devices affected
    38 at 2 sites
    Known exploitation
    None reported
    Network exposure
    Clinical VLAN, internet access blocked
    Clinical criticality
    High
    Manufacturer patch
    Validated v2.4 available

    Score factors

    • Severity rated high by the advisory
    • Devices in use for medication delivery
    • Segmented network reduces exposure
    Each advisory match shows the affected devices and the factors behind the score, for an analyst to confirm.
  3. Step 3

    Planning the fix

    Clinical engineering and the owning department agree when devices can be taken out of use for the patch.

    SiteUnitDevicesWindowAgreed byStatus
    Example General4 West12Overnight, week 1Device ownerScheduled
    Example GeneralOncology9Overnight, week 1Device ownerScheduled
    Example GeneralPediatrics7Not yet agreedPendingAwaiting owner
    Example ClinicInfusion suite10Weekend, week 2Device ownerScheduled
    Clinical engineering and the owning department agree when devices can be taken out of use for the patch.
  4. Step 4

    A device that cannot be patched

    When no fix is available, compensating controls and the reason are recorded and sent for risk acceptance.

    BX-31554 · CT workstation, Example General Imaging

    Reason
    Manufacturer does not support an OS upgrade on this model
    Open findings
    3 high
    Replacement
    In capital plan, not yet funded
    Proposed review
    Sample date for review
    Approvers
    Security leader, Imaging director

    Compensating controls

    • Isolated network segment, imaging traffic only
    • Remote vendor access disabled except during supervised sessions
    • USB ports disabled, verified by clinical engineering
    When no fix is available, compensating controls and the reason are recorded and sent for risk acceptance.
  5. Step 5

    Responding to a new advisory

    From the moment an advisory is matched, the response is recorded step by step, with who did each part.

    Fictional advisory · Example patient monitor model

    1. Advisory matched to 64 devicesHub
    2. Match confirmed, finding createdDevice security analyst
    3. Manufacturer guidance attached: patch pending validationClinical engineering
    4. Monitors confirmed on segmented networkDevice security analyst
    5. Interim risk acceptance approvedSecurity leader and ICU director
    6. Validated patch scheduledClinical engineering
    From the moment an advisory is matched, the response is recorded step by step, with who did each part.
  6. Step 6

    Reviewing a purchase

    Before a new device model is bought, its security documentation and the manufacturer's answers are reviewed and decided.

    Example ultrasound system (fictional) · Requested by Radiology

    MDS2
    Received
    SBOM
    Received
    Supported OS until
    Stated by manufacturer
    Remote service access
    Always-on by default
    Patch process
    Manufacturer-validated, quarterly

    Open issues

    • Remote access must be configurable to on-demand
    • Confirm components with known vulnerabilities in the SBOM
    Before a new device model is bought, its security documentation and the manufacturer's answers are reviewed and decided.

In the product

Annotated screens

The current build, with sample data. Select a numbered marker to read what it shows; the same notes are listed under the screen.

Medical Device Cybersecurity Hub in Moraph Apps: the product home for a sample organization, with the Device security panel; counts for devices in service, high-criticality devices with critical or high findings, critical or high risk findings, findings past target date; workflow stages (Devices: Recorded, In service, Pending replacement, Retired, Duplicate or not a device). All names and values are sample data.
Medical Device Cybersecurity Hub as it runs in the current build of Moraph Apps, with sample data (build d889d9719, 2026-11-08). Records, names and figures are placeholders, not client data.
Notes on this screen (4)
  1. Product navigation This product’s own pages, then the records, tasks, calendar, search and activity every Moraph product shares.
  2. New device Creates a record in this product. A person fills it in; the product checks it against its rules before saving.
  3. Workflow Records in each stage. Select a stage to see its records.
  4. Your work Open tasks, records assigned to you, overdue records and open records in this product, counted from its records.

Workflows

The principal workflows

  1. Inventory

    Device records exported from your clinical engineering system are joined with what your network discovery tools export, so each device has one record with its model, software version, location, owner and network details.

    5 steps
    • Asset records loaded from the clinical engineering system as CSV or through the Work API
    • Network discovery exports loaded as CSV from the tools you already run, or through the Work API
    • Discovery records are matched on MAC address, serial number and asset tag
    • Unmatched devices and conflicting details are queued for review
    • Each device is assigned an owning department and a clinical criticality
  2. Assess

    Published vulnerabilities and manufacturer security bulletins, recorded by staff or loaded through the Work API, are matched to device models, software versions and SBOM components, and each match is scored for your environment.

    5 steps
    • Each vulnerability or advisory, when saved, is matched against models and versions in the inventory
    • Matches are listed with the affected devices and their locations
    • Analyst confirms or rejects each match and records the reason
    • Risk scored from severity, known exploitation, network exposure and clinical criticality
    • Matches are assigned to the person responsible for the device
  3. Remediate

    Each finding is tracked to a patch, a compensating control or a documented risk acceptance, with the manufacturer's position and the clinical downtime it needs recorded along the way.

    5 steps
    • Manufacturer guidance and validated patch availability recorded on the finding
    • Patch or upgrade scheduled with the owning department to fit clinical use
    • Compensating controls such as network segmentation recorded where no patch is available
    • Completion verified against the next inventory or discovery update
    • Finding closed with evidence, or sent for risk acceptance
  4. Govern

    Devices that cannot be patched are accepted as risks by the people with authority to do so, with an expiry date, and reviewed again. Purchases are reviewed for security before they arrive.

    5 steps
    • Risk acceptance requested with the reason, controls in place and proposed review date
    • Security leader and device owner approve or return the request
    • Accepted risks reviewed before their expiry
    • New device purchases reviewed against the manufacturer's MDS2 and SBOM
    • Device risk reported to the risk or security committee

Roles and permissions

Who does what in the product

Your organization's administrators and technical leads give each person one of the roles below in the Moraph Portal under People and access. Each time someone's product access is given, changed or removed, it is recorded in the product's Activity.

Show each role and the permissions matrix

Viewer

People who need to see the program without changing it, such as auditors and external assessors

Sees the workspace without changing it.

Sees

  • Every device, vulnerability, remediation finding, risk acceptance, model profile and purchase review in the workspace, with the dashboard and reports; access isn't limited by site or department
  • Tasks and progress across the workspace

Does

  • Reads devices, findings, acceptances, purchase reviews, reports and the audit trail extract
  • Exports the inventory, findings and reports as CSV files

Cannot

  • Add, change or move records, load devices or SBOMs, or confirm or reject matches
  • Record an approval on a risk acceptance
  • Change Hub settings
Approvals
None.
Notified about
Nothing from the product, unless a record or task is assigned to them.

User

Device security analysts, clinical engineering technicians, device owners and procurement reviewers

Does the day-to-day work: tasks, records and workflow steps.

Sees

  • Every device, vulnerability, remediation finding, risk acceptance, model profile and purchase review in the workspace, with the dashboard and reports; access isn't limited by site or department
  • Tasks and progress across the workspace
  • Their own tasks and the rest of the team's

Does

  • Loads devices, discovery results and SBOMs, reconciles the inventory and records vulnerabilities
  • Confirms or rejects matches (a rejection needs a reason) and works findings to patched, not affected or risk accepted
  • Records compensating controls, campaigns and downtime
  • Drafts risk acceptances and records the device owner approval on acceptances they didn't draft
  • Runs purchase reviews and approves or declines those with no open issues recorded, with the reviewer and decision date
  • Imports records from a CSV file and exports lists and reports

Cannot

  • Record the security approval on a risk acceptance
  • Approve a risk acceptance they drafted (created or changed its terms), or give both approvals on one acceptance
  • Accept a risk without two recorded approvals from different people and an expiry within the maximum term
  • Mark a finding patched without an installed version that is no longer affected
  • Change an accepted risk acceptance: it is renewed instead
  • Approve or decline a purchase review with open issues recorded (such as a missing MDS2): a product administrator decides it
  • Clear the open issues recorded on a purchase review, except on their own draft that is still in Requested and only they have written: a product administrator does
  • Change Hub settings
Approvals
Records the device owner approval on a risk acceptance they didn't draft, while Hub settings have approvals recorded in the Hub (the default). Approves or declines purchase reviews with no open issues recorded.
Notified about
When a record or task is assigned to them (matches to assess, findings past target or showing an affected version again, acceptances to review or expired, end of support, controls to re-verify), and when work assigned to them is due soon or overdue.

Product administrator

The people who run the product for your organization, such as the security leader

Everything a User can do, plus the product's settings and reference data.

Sees

  • Every device, vulnerability, remediation finding, risk acceptance, model profile and purchase review in the workspace, with the dashboard and reports; access isn't limited by site or department
  • Tasks and progress across the workspace
  • Hub settings
  • Recently deleted records

Does

  • Records the security approval on risk acceptances they didn't draft
  • Approves or declines purchase reviews with open issues recorded (such as a missing MDS2); approving one needs conditions of approval
  • Sets Hub settings: target days, scoring weights and thresholds, how acceptances are approved, the maximum acceptance term, reminder lead times, purchase rating points, posture tasks and the patient information removal rule
  • Changes the workspace's record types, fields and workflow stages, and manages Work API keys
  • Restores deleted records

Cannot

  • Give people access to the product or change their roles: your organization's administrators and technical leads do that in the Moraph Portal under People and access
  • Approve a risk acceptance they drafted, or give both approvals on one acceptance
Approvals
Records the security approval on risk acceptances, while Hub settings have approvals recorded in the Hub (the default); the device owner approval comes from someone else, and neither approver may have drafted the acceptance. Hub settings can switch to typed approver names for approvals recorded elsewhere. Approves or declines purchase reviews with open issues recorded.
Notified about
When a record or task is assigned to them, and when work assigned to them is due soon or overdue.

Permissions at a glance

ActionViewerUserProduct administrator
See every device, finding, acceptance, purchase review and reportFullFullFull
Export lists and reports as CSV filesFullFullFull
Load and reconcile devices, and record vulnerabilitiesNo accessFullFull
Confirm or reject matches and work findingsNo accessFullFull
Draft a risk acceptanceNo accessFullFull
Record the device owner approval on a risk acceptance (not one they drafted)No accessApprovesApproves
Record the security approval on a risk acceptance (not one they drafted)No accessNo accessApproves
Approve or decline a purchase review with no open issues recordedNo accessFullFull
Approve or decline a purchase review with open issues recordedNo accessNo accessApproves
Change Hub settingsNo accessNo accessFull
Change the workspace settings and restore deleted recordsNo accessNo accessFull
Give people access and roles (in the Moraph Portal, by your organization's administrators and technical leads)No accessNo accessNo access
  • Full
  • Approves
  • No access

How access is controlled

  • A risk acceptance is accepted only with two approvals from different people and an expiry within the maximum term in Hub settings. By default the approvals are recorded in the Hub: the security approval by a product administrator and the device owner approval by someone else, neither of whom drafted it; changing its terms clears them. Hub settings can switch to typed approver names for approvals recorded elsewhere.
  • A purchase review with open issues recorded (such as a missing MDS2) is approved or declined by a product administrator (the security leader); Users decide reviews with no open issues, and only a product administrator clears a review's open issues, except a User's own draft still in Requested that only they have written.
  • Lists and reports filter by site and department, but access isn't limited by department: everyone with access sees every department's devices.
  • Roles are given to each person by your organization's administrators and technical leads in the Moraph Portal under People and access.
  • Each time someone's product access is given, changed or removed, it is recorded in the product's Activity.

Features

What it does

Unified device inventory

One record per device combining clinical engineering data and network discovery, with model, software version, location, owner and connection details.

Reconciliation queue

Devices seen on the network but missing from clinical engineering records, and records with conflicting details, are listed for someone to resolve.

Vulnerability matching

Published vulnerabilities, CISA Known Exploited Vulnerabilities entries and manufacturer advisories, recorded by staff or loaded through the Work API, matched to models and software versions, with each match confirmed or rejected by an analyst.

Clinical risk scoring

Findings ranked by points for severity, known exploitation and network exposure, weighted by how critical the device is to patient care, with weights you set and the factors shown on each finding.

Patch and manufacturer status

Whether the manufacturer has validated a patch, the version installed, and what the manufacturer recommends in the meantime, recorded on each device.

Compensating controls

Network segmentation, access restrictions and other controls recorded against the devices they protect, with who verified them and when.

Risk acceptance register

Requests to accept risk on devices that cannot be remediated, with approvers, conditions and an expiry date that triggers review.

End-of-support tracking

Devices running operating systems or software the manufacturer no longer supports, flagged with their location and replacement plans.

MDS2 and SBOM library

Manufacturer disclosure statements and software bills of materials stored by model, and used to match components to new vulnerabilities.

Pre-purchase security review

A review step for new device purchases, recording the security questions asked, the manufacturer's answers and the decision.

Advisory response

When a new advisory is recorded, one view shows every affected device, its location and owner, and the progress of the response.

Audit trail

Who changed what, when and why for every device, finding, control and risk acceptance, exportable for auditors and your risk committee.

Reporting

What you can report on

11 standard reports, grouped by who uses them. Each shows who it is for, how it can be broken down, how it is delivered and what it is used for. The data behind them is also available to your own reporting tools.

Show all 11 reports

Operational

Open findings by risk

For device security analysts and the security leader

Every open finding with its risk score, affected devices, owner, status and age, highest risk first.

Break down by
Risk level, Site, Department, Manufacturer, Status
Delivered as
Live dashboard; CSV export
Used for
Deciding what to work on next and making sure nothing high-risk sits unassigned.

Advisory response tracker

For device security analysts, clinical engineering, security leader

For a selected advisory or vulnerability, every affected device, where it is, who owns it and how far the response has got.

Break down by
Advisory, Site, Department, Response status
Delivered as
Live view
Used for
Answering leadership's question of which devices are affected and what has been done.

Reconciliation backlog

For clinical engineering and device security analysts

Devices seen on the network but not in clinical engineering records, and records with conflicting details, with how long each has been open.

Break down by
Site, Issue type, Device category, Age band
Delivered as
Live dashboard; CSV export
Used for
Keeping the inventory complete enough to trust.

Patch status by model

For clinical engineering

For each model, the installed software versions, whether a manufacturer-validated patch exists, and how many devices still need it.

Break down by
Manufacturer, Model, Software version, Site
Delivered as
Live dashboard; CSV export
Used for
Planning patch rounds and maintenance windows.

Management and committee

Device risk summary

For security leader, risk committee and board

A periodic summary of inventory coverage, open findings by risk level, findings past target date, accepted risks and end-of-support devices.

Break down by
Period, Hospital or site, Risk level
Delivered as
Printable page
Used for
Giving leadership the information to oversee medical device cyber risk.

End-of-support devices

For security leader, clinical engineering, capital planning

Devices running software or operating systems the manufacturer no longer supports, with their controls and any replacement plan.

Break down by
Department, Device category, Operating system, Replacement status
Delivered as
Live view; CSV export
Used for
Informing capital replacement decisions and showing that unsupported devices are protected in the meantime.

Department device risk

For device owners and department leaders

Each department's devices, their open findings, planned work and accepted risks.

Break down by
Department, Device category, Risk level, Planned work
Delivered as
Live view
Used for
Keeping department leaders informed about the devices they own.

Risk and audit

Risk acceptance register

For security leader, compliance, auditors

Every risk acceptance with the reason, controls in place, approvers, conditions, expiry date and review history.

Break down by
Status, Department, Expiry window, Approver
Delivered as
Live view; CSV export
Used for
Showing that unremediated risk was accepted by the right people and is reviewed.

Compensating control verification

For device security analysts, auditors

Each recorded control, the devices it protects, who verified it and when it is next due for verification.

Break down by
Control type, Site, Verification status, Due date
Delivered as
Live view; CSV export
Used for
Evidencing that controls on unpatched devices are in place and checked.

Audit trail extract

For internal audit and compliance

Who did what, when and why for a selected device, finding, risk acceptance or period, including notes, decisions and approvals.

Break down by
Record, User, Action, Date range
Delivered as
In the product; CSV export
Used for
Answering auditor and risk analysis requests for evidence without assembling it by hand.

Procurement

Pre-purchase review log

For supply chain, security leader

Each pre-purchase security review, the documents received, open issues and the decision.

Break down by
Manufacturer, Decision, Requesting department, Period
Delivered as
Live view; CSV export
Used for
Showing that device security is considered before purchase, and following up on conditions.
Exports, access and evidence
  • Most reports can be exported to CSV, and the device risk summary is laid out for printing. Follow-ups arrive as tasks rather than as scheduled report emails.
  • Each report can be filtered and the filters saved, so an analyst, a clinical engineering lead or a department director can keep their own views.
  • Device, finding and risk data is available through the Moraph Work API, and can be delivered to your data warehouse or business intelligence tool alongside other security and asset data.
  • Reports can be filtered to a site or department, so a department director can follow their own devices, and auditors can be given read-only access.
  • The audit trail extract shows who did what and when for any record, person or period. Exports of the shared records list are recorded in the product's activity.

Integrations

The systems it works alongside

Medical Device Cybersecurity Hub: related requirements and the systems it connects toRelated requirementsWorks alongsideMedical Device Cybersecurity HubHIPAA Security Rule (45 CFR Part 164, Subpart C)HIPAAFDA postmarket cybersecurity guidance for medical devices: FDA guidance: Postmarket Management of Cybersecurity in Medical DevicesFDA postmarket cybersecurity guidance for medical devicesFederal Food, Drug, and Cosmetic Act Section 524B (ensuring cybersecurity of devices)Federal Food, Drug, and Cosmetic Act Section 524B (ensuring cybersecurity of…HHS 405(d) Health Industry Cybersecurity Practices (HICP)HHS 405(d) Health Industry Cybersecurity PracticesIEC 80001-1: ANSI/AAMI/IEC 80001-1 (safety, effectiveness and security in networks incorporating medical devices)IEC 80001-1Manufacturer Disclosure Statement for Medical Device Security (MDS2)Manufacturer Disclosure Statement for Medical Device Security (MDS2)Clinical engineering system (CMMS): Asset records, models, locations and owning departments exported from your computerized maintenance management system, loaded as CSV or sent through the Work API.Clinical engineering system (CMMS)Network discovery tools: Device exports from the passive network monitoring or medical device discovery tools you already run, loaded as CSV or through the Work API.Network discovery toolsVulnerability and advisory feeds: Entries from the National Vulnerability Database, the CISA Known Exploited Vulnerabilities catalog, CISA medical advisories and manufacturer security bulletins, recorded by staff or loaded through the Work API; there is no built-in feed.Vulnerability and advisory feedsIT service management: Your service desk team can read remediations through the Work API and raise tickets, writing the ticket number and status back to the finding.IT service managementNetwork access control: Segmentation and access policies recorded by staff as compensating controls, or loaded through the Work API, including from Moraph's Network Access Control managed service.Network access controlSign-in: Staff sign in with their Moraph account, using email and password and, optionally, two-step verification. Sign-in through your own identity provider (SAML or OpenID Connect) is not offered.Sign-inWork API: Device, finding and risk data available to your data warehouse and reporting tools through the Moraph Work API.Work API

Related requirements

Medical Device Cybersecurity Hub

Works alongside

Each requirement links to its requirement page and each system to the integrations directory. Meeting a requirement remains your organization’s responsibility.
The diagram as a list

Related requirements

  • HIPAAHIPAA Security Rule (45 CFR Part 164, Subpart C)
  • FDA postmarket cybersecurity guidance for medical devicesFDA guidance: Postmarket Management of Cybersecurity in Medical Devices
  • Federal Food, Drug, and Cosmetic Act Section 524B (ensuring cybersecurity of devices)Federal Food, Drug, and Cosmetic Act Section 524B (ensuring cybersecurity of devices)
  • HHS 405(d) Health Industry Cybersecurity PracticesHHS 405(d) Health Industry Cybersecurity Practices (HICP)
  • IEC 80001-1ANSI/AAMI/IEC 80001-1 (safety, effectiveness and security in networks incorporating medical devices)
  • Manufacturer Disclosure Statement for Medical Device Security (MDS2)Manufacturer Disclosure Statement for Medical Device Security (MDS2)

Works alongside

  • Clinical engineering system (CMMS)Clinical engineering system (CMMS): Asset records, models, locations and owning departments exported from your computerized maintenance management system, loaded as CSV or sent through the Work API.
  • Network discovery toolsNetwork discovery tools: Device exports from the passive network monitoring or medical device discovery tools you already run, loaded as CSV or through the Work API.
  • Vulnerability and advisory feedsVulnerability and advisory feeds: Entries from the National Vulnerability Database, the CISA Known Exploited Vulnerabilities catalog, CISA medical advisories and manufacturer security bulletins, recorded by staff or loaded through the Work API; there is no built-in feed.
  • IT service managementIT service management: Your service desk team can read remediations through the Work API and raise tickets, writing the ticket number and status back to the finding.
  • Network access controlNetwork access control: Segmentation and access policies recorded by staff as compensating controls, or loaded through the Work API, including from Moraph's Network Access Control managed service.
  • Sign-inSign-in: Staff sign in with their Moraph account, using email and password and, optionally, two-step verification. Sign-in through your own identity provider (SAML or OpenID Connect) is not offered.
  • Work APIWork API: Device, finding and risk data available to your data warehouse and reporting tools through the Moraph Work API.
How data moves with each system (7)
Works alongsideHowWhat flows
Clinical engineering system (CMMS)Asset records, models, locations and owning departments exported from your computerized maintenance management system, loaded as CSV or sent through the Work API.In: asset tags, models, serial numbers, locations and owning departments. Out: patch and finding status, read through the Work API by your CMMS team.
Network discovery toolsDevice exports from the passive network monitoring or medical device discovery tools you already run, loaded as CSV or through the Work API.In: IP and MAC addresses, observed software versions, network segment and last-seen date.
Vulnerability and advisory feedsEntries from the National Vulnerability Database, the CISA Known Exploited Vulnerabilities catalog, CISA medical advisories and manufacturer security bulletins, recorded by staff or loaded through the Work API; there is no built-in feed.In: vulnerability identifiers, affected products and versions, severity and exploitation status.
IT service managementYour service desk team can read remediations through the Work API and raise tickets, writing the ticket number and status back to the finding.Out: remediation records. In: ticket numbers and status written back through the Work API.
Network access controlSegmentation and access policies recorded by staff as compensating controls, or loaded through the Work API, including from Moraph's Network Access Control managed service.In: device segment and policy assignments.
Sign-inStaff sign in with their Moraph account, using email and password and, optionally, two-step verification. Sign-in through your own identity provider (SAML or OpenID Connect) is not offered.None: accounts are kept in Moraph
Work APIDevice, finding and risk data available to your data warehouse and reporting tools through the Moraph Work API.Out: devices, findings, controls, risk acceptances and status.

The product doesn’t connect to these systems itself: data moves through the Moraph Work API, CSV import, exports or staff entry, as each row says.

Security and evidence

How your data is protected

Sign-in

Staff sign in with their Moraph account, using email and password and, optionally, two-step verification.

Role-based access

What each person can do follows their role; requesting a risk acceptance is separate from approving one.

Encryption and keys

Client data is encrypted.

Complete audit trail

Every change and decision is logged with the person and time, and the product offers no way to edit that history.

Data residency

Data is hosted on Cloudflare's network, in a database that is not restricted to a jurisdiction.

Business associate agreement

The Hub holds device data, not patient records. Where your use could involve PHI, ask us about a business associate agreement.

The evidence trail

What Medical Device Cybersecurity Hub records, and the reports that show it to a reviewer.

  1. Recorded

    Complete audit trail

    Every change and decision is logged with the person and time, and the product offers no way to edit that history.

  2. Audit evidence

    Compensating control verification

    Each recorded control, the devices it protects, who verified it and when it is next due for verification.

Request security information

Company-wide controls, data residency and subprocessors are described in our Trust Center, where you can send a request for security information.

Deployment

Where and how it runs

Moraph cloud

Hosted and operated by Moraph on Cloudflare's network.

With a managed service

Optionally run alongside Moraph managed services, such as Network Access Control, for help applying compensating controls.

Moraph Apps, and how the product is put together

Runs in Moraph Apps, the workspace shared by every Moraph-built product. Sign-in, roles, the audit trail, reports and the Work API are the same in every product; record types, fields, stages, roles and reports are configured for your organization during implementation, and anything beyond configuration is scoped as project work.

How a Moraph product is put together Your staff sign in once through the Moraph client portal and use the product in Moraph Apps, which runs on Cloudflare's global network and provides records, workflow, tasks, search, roles and the audit trail. The product's own services and your primary data run on Cloudflare too: the database is stored in one Cloudflare location and is not restricted to a jurisdiction. Your systems connect to the product through the Work API and the integrations agreed in the design. Your organization Your staffbrowser or mobile Your systemsyour existing software Cloudflare global network Client portalone Moraph sign-in, two-step, roles Moraph Apps records, workflow stages, taskssearch, reports, rolesaudit trailWork API (/api/v1) Moraph data on Cloudflare Product servicesthe product’s own processingand integrations Primary dataone database, not restrictedto a jurisdiction
How every Moraph product is put together. Sign-in and the shared workspace run on Cloudflare’s global network; the product’s own services and your primary data run there too, in a database that is not restricted to a jurisdiction. Each integration is specified in the design.

Security controls and data residency are set out in our Trust Center. Engagement models and what drives a quotation are on Working with Moraph.

Implementation

What a rollout involves

Every implementation follows the same phases, described on Working with Moraph. Their length depends on scope, so the plan in your proposal gives the dates.

  1. Discovery
  2. Design
  3. Implementation
  4. Migration
  5. Testing
  6. Go-live
  7. Ongoing operations

For Medical Device Cybersecurity Hub, the work involves

  • Data sources

    We map the exports from your clinical engineering system and network discovery tools to the Hub's loads and agree how often they are loaded. We need data extracts and contacts from clinical engineering and the security team.

  • Inventory reconciliation

    Initial records are matched, and conflicts and unmatched devices are worked through with your teams so the inventory starts from an agreed baseline.

  • Risk policy

    Scoring factors, clinical criticality categories and target dates by risk level are set with your security leader and documented.

  • Workflow and roles

    Sites, departments, assignment rules, approval steps and roles are configured to match how your clinical engineering and security teams work together.

  • Existing findings

    Open findings, controls and risk acceptances from your current spreadsheets or tools are loaded and reviewed, so history is not lost.

  • Training and go-live

    Analysts, clinical engineering staff, approvers and department leaders are trained on their own parts of the workflow.

Release notes

Release history

Medical Device Cybersecurity Hub

Generally available
End of support
None announced. At least 12 months’ notice before any end of support.

No version history is published for this product.

What the stages mean, how versions work and our end-of-support policy: Product lifecycle.

Limitations

What it does not do

Worth knowing before you evaluate it.

  • The Hub does not scan or probe devices itself. It relies on your clinical engineering records and the network discovery tools you already run, and its inventory is only as complete as those sources.
  • It does not patch devices. Patches and upgrades are applied by your clinical engineering staff or the manufacturer, once the manufacturer has validated them.
  • Vulnerability matching depends on accurate model and software version data and on what manufacturers publish. Matches are confirmed by an analyst before they become findings.
  • It is not a network access control or intrusion detection system. It records the controls your network tools enforce but does not enforce them.
  • Risk scores support your decisions; risk acceptance and remediation priorities are decided by the people you designate.
  • It does not perform the manufacturer's regulatory obligations, such as premarket cybersecurity submissions, and is not itself a regulated medical device.
  • It is not designed to store patient records; device data and logs containing PHI should be kept out of the Hub unless agreed under a business associate agreement.
  • Non-medical IoT and general IT assets can be recorded, but the workflows are designed for clinical devices.

Evaluation checklist

What to test in a demonstration or pilot

Questions worth putting to us, and to any other vendor you are considering.

  1. Load an extract from your clinical engineering system and your discovery tool and review how well the records match
  2. Pick a recent manufacturer advisory and check whether the Hub finds the devices you know are affected
  3. Ask a clinical engineering technician to record a patch and see how the finding closes
  4. Walk through a risk acceptance for an unsupported device, including both approvals
  5. Check the department device risk report for one department
  6. Review the device risk summary as your risk committee would receive it

Questions

Frequently asked questions

Does the Hub replace our network discovery tool?

No. It holds the device data you load from the discovery tools you already run and combines it with your clinical engineering records. It does not scan devices itself.

Who owns the data in the Hub?

Your organization does. How it is returned to you and deleted at the end of the agreement is set out in the contract.

Will Moraph sign a business associate agreement?

Where your use of the Hub could involve PHI, ask us about a business associate agreement. The Hub is designed to hold device data rather than patient records.

Can we change how findings are scored?

Yes. Scoring factors, clinical criticality categories and target dates are set with your security leader during implementation and can be changed later, with each change recorded.

How is it priced?

As a subscription, usually measured by the number of devices or sites covered, with implementation charged separately. See Working with Moraph for what drives a quotation.

Is there an accessibility conformance report?

Ask for one through the procurement request form at /how-to-buy/request, naming the version you are evaluating.